Intruder alarm integration
A dedicated port for input and output signals is provided when integrating a Net2 plus ACU with an alarm system.
Please see AN1035 - Integrating Net2 with an intruder alarm system < http://paxton.info/91 > or call Technical
Support for further information.
Arm - Conrmation Push Button - Wire across 0V and Arm.
Sense - Requires a voltage free loop across 0V and Sense to conrm when alarm is active.
Set - Relay provides contacts across COM and N.O. for a voltage free loop to set the alarm.
Reader 1: Settings for Reader 1 and Keypad 1 on the ACU.
Reader 2: Settings for Reader 2 and Keypad 2 on the ACU.
Alarm: Contains settings for the different types of alarm.
Codes: Valid codes can be viewed, added and removed.
(Can only be viewed when a keypad is active).
Events: Shows the events for the control unit selected.
Name: Each reader can be named individually if required.
Reader type: Set the reader type, if applicable.
Keypad type: Set the keypad type, if applicable.
Token data format: Select the data type being used on
the system. (New formats can be created).
Reader operating mode: Set the operating mode.
Timed operating modes: A different operating
mode can be congured within a time window.
Reader action: Set the action required
when access is granted.
Software Conguration
Door name: Name the Door.
Door open time: Set the door open time.
Unlock the Door during: Holds the door unlocked during
this timezone. - Set to 'At No Time' for normal user
operation.
PC Installation
The current specication for compatible PC hardware, network and operating systems is available on our website at
the following link: http://paxton.info/720