Page
1
1 redaeR
:noi
tuaC ylno sredaer CD V21 roF
2 red
aeR
12V
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V
0V
12V
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V
N.C.
N.O.
COM
N.C.
N.O.
COM
Alarm
12V
Green LED
Exit
0V
stupnI
tputsuO
rewoP
0V
12V
Contact
0V
0V
Tamper
PSU
repmaT/USP
tcatnoC
nottuB tixE
2 yaleR
1 yaleR
Expansion
Rx
Tx
RS485 Network
CAT5 Cable Coding
nrG/thW
eraps ro neercS
atad morf seroc
e
lbac
nee
rG
gnrO/thW
egn
arO
10/100 Ethernet
Server Connected
Server Link
100
10
End of Line Termination
ON
OFF
Net2 plus
Intruder Alarm
Set
V0
mrA
esneS
MOC
.O.N
LABEL HERE
LABEL HERE
http://paxton.info/107
123456
00-01-02-03-04-05
2345612
Exit button
(push to make)
Reader/keypad
Tamper switch
(optional)
Door contact switch
(held closed by door)
30/08/2012
12V DC
power supply
12V (Green) - Power LED.
Relay 1 (Orange) - The relay is energised - (N.O./COM contacts are closed).
Relay 2 (Orange) - The relay is energised - (N.O./COM contacts are closed).
Alarm (Red) - 12V Alarm output is active.
Exit (Orange) - The exit button contacts are closed.
Contact (Orange) - The door contacts are closed.
Tamper (Orange) - The tamper contacts are closed.
PSU (Orange) - The PSU contacts are closed.
OK (Green ash) - The internal software is running.
Termination (Red) - The on-board resistors are in place across the RS485 data pairs.
Rx (Red) - The ACU is receiving data (TCP/IP or RS485) - See also FAQ section.
Tx (Green) - The ACU is responding to data - (TCP/IP or RS485).
Server Connected (Green) - The TCP/IP interface is communicating with the PC Net2 server.
Server Link - Green = 100 Mbit/s : Orange = 10 Mbit/s (TCP/IP speed).
Switchable
120 ohm
resistors
The Net2 plus ACU has 2 reader ports and
3 output relays, but can control just one
door. The conguration of one control
unit per door greatly simplies installation
and is ultimately highly cost effective.
Intruder alarm integration
TCP/IP patch lead
To next
ACU
From previous
ACU
The Net2 plus can be connected to the PC via an RS485 data line or a TCP/IP connection.
This unit requires the controlling PC to be running Net2 v4.14 or later software.
For a fail open lock
(Maglock), wire 0V to the
"N.C." terminal instead of
"N.O."
*
Fail closed release
LED indications
Wiring
Ins-30080 Net2 plus control unit
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/